Ph Electrodes

Ph Electrodes

Product Details:

  • Features High sensitivity, Fast response, Easy calibration, High accuracy
  • Application pH measurement in chemical, biological, and environmental samples
  • Function Measures pH value of solutions
  • Automatic Grade Manual
  • Connectivity Type Cable
  • IP Rating IP54
  • Size Standard laboratory size, Length (approx) 12-15 cm
  • Click to View more
X

Ph Electrodes Product Specifications

  • pH measurement in chemical, biological, and environmental samples
  • Glass with internal reference electrode
  • High sensitivity, Fast response, Easy calibration, High accuracy
  • pH range 0-14
  • Manual
  • Measures pH value of solutions
  • BNC Connector
  • Standard laboratory size, Length (approx) 12-15 cm
  • Transparent/White
  • IP54
  • Cable
  • 0.02 pH
  • pH Electrode
  • Laboratory, industrial, and field analysis
  • No
  • < 10 seconds
  • Rinse with distilled water after use and store in appropriate solution
  • 1 meter (typical)
  • 0 to 60°C
  • Standard pH meters with BNC input
  • Ceramic single or double junction
  • No (sealed unit)
  • KCl solution
  • Ag/AgCl

Product Description

Ph Electrodes 

Electrodes

PH Electrodes are made with high-quality materials and cutting-edge procedures under the supervision of our experts. Because of their exceptional performance, the provided electrodes are in high demand. Customers can order the provided electrodes in a variety of specifications to suit their needs. They are very effective and simple to make. PH Electrodes are precisely constructed and safe to use. They have a good level of repeatability. These electrodes are tested under various parameters to ensure their high quality and excellent performance. They are very effective as well as economical and great to utilize.  

Product Details:

Application

Laboratory

pH, Conductivity, DO, Ion, ORP Sensors & Electrodes

Features

  • pH and Reference Electrodes
  • Conductivity Probes
  • Ion-Selective Electrodes
  • Dissolve Oxygen Sensors
  • ORP/Redox Electrodes
  • LE Sensors

 

These electrodes combine innovative technologies and a tradition in glassblowing for fast, accurate and reliable pH, ORP, conductivity, ion-selective and dissolved oxygen measurements. High precision and reliability as well as low maintenance make them the best choice for a wide range of applications.



Fast and Accurate pH Sensing

This electrode delivers pH readings in less than 10 seconds, making it ideal for applications demanding quick results. Its high sensitivity and 0.02 pH accuracy ensure reliable data for laboratory, industrial, or environmental testing. The electrodes design supports easy calibration and stable performance over a wide pH range.


Durable and User-Friendly Construction

Built with a transparent or white glass body and an internal Ag/AgCl reference electrode, this pH sensor is robust for regular use. The ceramic junction (single or double) optimizes ion flow, enhancing measurement stability. The sealed unit is non-replaceable, maintenance is simplified, and its manual operation ensures control over calibration and measurement.


Versatile Applications and Compatibility

With a standard BNC connector and one-meter cable, this electrode easily interfaces with most laboratory pH meters. Suitable for chemical, biological, and environmental samples, it supports research, industrial quality assurance, and environmental monitoring. Its IP54 rating and versatile size make it fit for both bench-top and field analysis.

FAQs of Ph Electrodes:


Q: How should I properly maintain the pH electrode for optimal longevity?

A: To maintain the electrode, rinse it with distilled water after every use to remove any residues. Store it in a KCl solution when not in use to keep the glass membrane and junction hydrated, as this preserves the sensors response time and accuracy.

Q: What processes are supported by this pH electrode?

A: This electrode is well-suited for measuring pH in chemical, biological, and environmental samples. Its fast response time and high accuracy benefit laboratory analyses, industrial quality checks, and field-based monitoring.

Q: When should calibration be performed on the electrode?

A: Calibration should be carried out regularly, ideally before each series of measurements, or whenever accuracy is critical. Using standard buffer solutions ensures the readouts remain precise.

Q: Where can this electrode be used, and with which meters is it compatible?

A: Its compatible with any standard pH meter featuring a BNC input, commonly found in laboratories, research facilities, and fieldwork patrols. The electrodes versatility allows it to be used in educational, industrial, and environmental settings across India.

Q: What are the key benefits of this pH electrode?

A: Key benefits include swift response (under 10 seconds), high sensitivity, excellent accuracy (0.02 pH), and ease of calibration. The robust glass construction and ceramic junction enhance durability and reliability in diverse environments.

Q: How do I connect and use the pH electrode with my meter?

A: Simply attach the electrodes BNC connector to your pH meters compatible input. Immerse the glass bulb in your sample, avoid air bubbles on the membrane, and manually calibrate if neededyour meter will then display the pH value.

Q: Can this pH electrode be sterilized or have its reference replaced?

A: No, this model is a sealed unit, meaning the reference is not replaceable and the electrode cannot be sterilized. For maintenance, rely on proper rinsing and recommended storage in KCl solution.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Laboratory Consumables & Accessories' category



Back to top
trade india member
Mettler-Toledo India Private Limited All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.