TOC Pump Module

TOC Pump Module

Product Details:

  • Response Time <3 seconds
  • Accuracy 2% F.S.
  • Interface Type Standard connector (RS232 optional)
  • Temperature 545C
  • Automation Grade Automatic
  • Features Corrosion-resistant, high chemical compatibility, compact design
  • Display Type LED status indicator
  • Click to View more
X

TOC Pump Module Product Specifications

  • LED status indicator
  • 24 V DC
  • Automatic
  • 50/60 Hz
  • Panel or Frame Mount
  • 24 V DC
  • 0.30.4 MPa
  • 1.3 kg
  • 1085% RH (non-condensing)
  • TOC Pump Module
  • Corrosion-resistant, high chemical compatibility, compact design
  • Automatic
  • 1/4 inch
  • 1.05.0 mL/min
  • Standard connector (RS232 optional)
  • Laboratory or Online TOC Analysis
  • 545C
  • For TOC Analyzer Liquid Delivery
  • <3 seconds
  • 2% F.S.
  • <50 dB
  • Purified Water, TOC Sample Solutions
  • IP65
  • Manual or Remote
  • >10,000 hours
  • PTFE, PPS, EPDM, FKM
  • Micro-Diaphragm Pump

TOC Pump Module Trade Information

  • Western Europe, Central America, Asia, Eastern Europe, Middle East, South America, North America, Australia, Africa
  • All India

Product Description

TOC Pump Module

For Reliable Sample Delivery

Provides a highly stable, metered flow of process water to the TOC sensor to ensure reliable and consistent TOC measurement performance.

For applications where system pressure is too low to provide adequate flow through the TOC sensor

For low-pressure applications where system pressure may vary routinely during operation

Specifications :-

  •     Colour: Blue and Off White
  •     Shape: Square
  •     Brand: Mettler-Toledo India Private Limited 

Product details

Application

Laboratory

I Deal In

New Only

Power

Electric

Brand

METTLER TOLEDO

Color

Blue and Off

Shape

Square

 

FAQ

1. What exactly is a TOC Pump Module?

Ans - Total organic carbon (TOC) in aqueous samples can be precisely measured using the TOC Pump Module. It is utilised in many different applications, such as laboratory research, industrial process control, and environmental monitoring.

2. Why does the TOC Pump Module function?

Ans - In order for the TOC Pump Module to function, a sample must first be purge through the sample chamber with a carrier gas, such as nitrogen. After being ionised, the sample is sent through an ionisation chamber to test the TOC. Parts per million (ppm) are then used to express the TOC reading.

3. What advantages come with employing the TOC Pump Module?

Ans - A few advantages of the TOC Pump Module are accuracy, practicality, and affordability. Additionally, it is simple to use and needs little upkeep.

4. Which samples can the TOC Pump Module analyse?

Ans - A number of aqueous samples, including ground water, surface water, wastewater, and industrial process water, can be measured using the TOC Pump Module.

5. What safety precautions should I take when utilising the TOC Pump Module?

Ans - Yes, it's crucial to abide by the manufacturer's safety guidelines when using the TOC Pump Module. This entails making sure the location is well-ventilated and donning safety gear including gloves, goggles, and a face mask. It's also critical to be aware of any potentially dangerous substances in the sample. 



Reliable Performance for TOC Analysis

The TOC Pump Module ensures consistent and precise liquid delivery for TOC analyzers. Its robust construction resists harsh chemicals, making it ideal for both laboratory and online analytical applications. This pump performs accurately even in demanding environments due to its broad operating humidity and temperature range, ensuring reliable operation for critical water quality monitoring.


Flexible Control and Easy Integration

The pump module supports both manual and remote flow adjustments, allowing users to adapt it to their specific workflows. An integrated LED status indicator provides instant operational feedback, and connectivity options include a standard connector with optional RS232 interface, ensuring easy integration into existing systems or new setups.


Designed for Longevity and Safety

Constructed from high-grade, corrosion-resistant materials, the pump achieves a protection grade of IP65, safeguarding against moisture and dust ingress. Its durable design, combined with a service life exceeding 10,000 operating hours, minimizes maintenance demands and ensures safety during continuous laboratory or field use.

FAQs of TOC Pump Module:


Q: How do I adjust the flow rate on the TOC Pump Module?

A: The flow rate can be adjusted either manually or remotely, giving users flexibility to match their systems requirements. Manual adjustments are made using accessible controls on the module, while remote adjustments can be achieved via automation interfaces if integrated.

Q: What liquids is this pump compatible with, and why is chemical resistance important?

A: The pump is designed for purified water and TOC sample solutions. Its construction from PTFE, PPS, EPDM, and FKM ensures high chemical compatibility and corrosion resistance, making it ideal for handling various analytical liquids without performance degradation.

Q: Where can the TOC Pump Module be installed?

A: The module features a compact design suitable for either panel or frame mounting. Its IP65 protection grade and robust materials enable installation in laboratory settings or online (field) analytical environments, where exposure to moisture and dust may be present.

Q: When should the pump module be serviced or replaced?

A: With a service life exceeding 10,000 hours, the pump requires minimal maintenance. Routine checks are recommended based on the applications demands, but its durable design means replacements are seldom needed during normal operational lifespans.

Q: What are the main benefits of using this pump module in TOC analysis?

A: Users benefit from highly accurate liquid delivery (2% F.S.), fast response time (<3 seconds), low noise operation (<50 dB), and easy integration and monitoring via the LED status indicator. Its automation grade and wide operational tolerances support reliable, long-term analytical use.

Q: How does the pump interface with other laboratory equipment?

A: The TOC Pump Module includes a standard connector and provides optional RS232 interface for seamless integration with many TOC analyzers or automated laboratory systems. This allows automation and remote control functions to be utilized efficiently.

Q: What is required for powering and operating the pump module?

A: The pump operates on a 24 V DC power supply and is compatible with both 50 Hz and 60 Hz frequencies. Its automatic control mode and status display ensure straightforward, reliable usage for laboratory personnel and automation systems.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Process Analytics' category



Back to top
trade india member
Mettler-Toledo India Private Limited All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.