DP70 Dropping Point System

DP70 Dropping Point System

Product Details:

  • Core Components Heating Block, Optical Sensor, Microprocessor Controller
  • Feature Fully Automatic Operation, Integrated Cooling
  • Voltage 220 V
  • Automation Grade Automatic
  • Capacity 2 samples per run
  • Temperature Range Room temperature to 400C
  • Measurement Range Up to 400C
  • Click to View more
X

DP70 Dropping Point System Product Specifications

  • 50/60 Hz
  • 0.2C
  • DP70
  • 7-inch Color Touchscreen Display
  • Automatic Dropping Point Apparatus
  • Fully Automatic Operation, Integrated Cooling
  • Heating Block, Optical Sensor, Microprocessor Controller
  • Testing Dropping Point of Various Substances
  • 2 samples per run
  • 220 V
  • Automatic
  • Room temperature to 400C
  • Approx. 10 kg
  • 420 x 320 x 300 mm
  • AC Mains
  • Up to 400C
  • Chemically Resistant Enclosure
  • USB, RS232, LAN Port
  • Optical
  • Capillary Tubes, Standard Weights, User Manual
  • Internal Memory and Export Option
  • User Programmable
  • Over-temperature Protection, Enclosed Chamber
  • Integrated Fan Cooling
  • ASTM D3954, ISO 4625

DP70 Dropping Point System Trade Information

  • Western Europe, Central America, North America, Eastern Europe, Middle East, South America, Asia, Australia, Africa
  • All India

Product Description

DP70 Dropping Point System

Optimized for testing a variety of samples, the DP70 offers One Click dropping and softening points. DP70 allows for duplicate determination and accurate result documentation.

The many other advantages available with this Excellence Dropping Point System include:

Compliance to industry norms and standards

Product details

Application Type

Industrial

Power

Electric

Need Test Result

2 to 6 Hours

Need Standard Certification

Yes

Delivery

Standard

Deal In

New Only

FAQ

1. The DP70 Dropping Point System is what, exactly?

Ans - A safety management system called the DP70 Dropping Point System is intended to stop unauthorised entry to locations where goods is loaded and unloaded. To make sure that only authorised workers can enter and exit the location, it combines sensors, video monitoring, and access control.

2. The DP70 Dropping Point System operates in what manner?

Ans - To monitor and control access to the loading and unloading area, the DP70 Dropping Point System combines sensors, video surveillance, and access control. The access control system demands that authorised workers produce legitimate credentials before entering when it detects the presence of people and vehicles in the area.

3. What advantages does using the DP70 Dropping Point System offer?

Ans - The DP70 Dropping Point System improves safety and security for the area used for loading and unloading. It stops unauthorised people from entering the area and works to stop theft, vandalism, and other bad behaviour.

4. How do I install a DP70 Dropping Point System?

Ans - To explore installation possibilities, get in touch with a certified DP70 Dropping Point System service provider. They may help with installation, setup, and maintenance as well as give you information on the system.

5. Which kind of upkeep is necessary for the DP70 Dropping Point System?

Ans - To keep the DP70 Dropping Point System in good working order, routine maintenance is required. This include ensuring that every component is operating well, replacing any worn or broken parts, and upgrading the software as necessary. Users should also adhere to any additional maintenance instructions given by the manufacturer.



Automatic Precision in Dropping Point Testing

The DP70 Dropping Point System provides automatic and reliable measurement of the dropping point in various samples. Its microprocessor-controlled heating block and optical sensor allow for highly accurate determinations, while programmable heating and integrated cooling ensure consistent results for substances up to 400C. The enclosed chamber, safety features, and extensive connectivity options make it ideal for modern laboratories and quality control environments.


Intuitive Operation and Data Management

A vibrant 7-inch color touchscreen organizes all controls, making setup, calibration, and observation straightforward. Internal memory enables secure data storage, with fast export available via USB, RS232, or LAN. User-friendly software streamlines test configuration, result retrieval, and compliance documentation, simplifying workflows for operators and ensuring traceability of results.

FAQs of DP70 Dropping Point System:


Q: How does the DP70 Dropping Point System ensure accurate and repeatable results?

A: The DP70 utilizes optical sample detection and a microprocessor-controlled heating block to deliver consistent temperature regulation and precise measurement, with accuracy up to 0.2C. Its automatic operation, programmable heating rates, and integrated fan cooling also help maintain standardized testing conditions.

Q: What substances can be tested with the DP70 Dropping Point Apparatus?

A: The DP70 can measure the dropping point of a wide range of substances, including fats, oils, waxes, and resins. Its broad measurement range from room temperature to 400C makes it versatile for various laboratory and industrial applications.

Q: When should I use the integrated cooling system during operation?

A: The integrated fan cooling system activates automatically after the test or when programmed to maintain the appropriate sample temperature. This ensures rapid cooling between runs, increases throughput, and prevents overheating for prolonged equipment life.

Q: Where can I export or store my measurement data from the DP70 system?

A: Measurement data can be securely stored in the instruments internal memory. For external access and archival, results can be easily exported via USB, RS232, or LAN ports, facilitating transfer to laboratory information management systems or PCs.

Q: What is the process for performing a test using the DP70 Dropping Point System?

A: To perform a test, insert capillary tubes containing the sample into the heating block, use the touchscreen to set test parameters, and start the run. The system will heat, detect, and record the dropping point automatically, then save the data for reporting or export.

Q: How does the DP70 enhance laboratory safety during testing?

A: Laboratory safety is optimized through over-temperature protection, an enclosed chamber reducing exposure risk, and the use of chemically resistant materials. Automated processes also limit direct handling, helping maintain a safe testing environment.

Q: What are the benefits of using the DP70 for my laboratory or production facility?

A: The DP70 offers rapid, accurate, and efficient dropping point determination with minimal operator intervention. Its compliance with ASTM and ISO standards ensures reliable results, while data management, safety features, and robust connectivity promote productivity and regulatory adherence.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Analytical Instruments' category



Back to top
trade india member
Mettler-Toledo India Private Limited All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.